Regulatory trackerCoverage and methodology
All findings
Australia · Australian Capital TerritoryIn force

ACT adopts lower aluminium welding fume WES on 9 September 2026

The Australian Capital Territory adopted the 1 mg/m³ eight-hour aluminium welding-fume standard on September 9, 2026. Its local commencement followed the November 2025 national-list revision.

Scope to keep in mind

This date establishes ACT commencement only. Other jurisdictions require their own adoption checks.

Legal status
in force
Source check
Sep 17, 2026
Topic
Aluminium welding fumes
Technical review
Jiaxi · 2026-09-23

What changed

Previous requirement

ACT aluminium welding WES was 5 mg/m3.

New requirement or current position

ACT WES is 1 mg/m3 8-hour TWA.

Who it affects

  • Boat and vehicle repair
  • Fabrication
  • Construction

Dates and milestones

Commencement and compliance dates can differ. Read the conditions beside each date, including any stay or local adoption requirement.

Announcement or publication
Aug 19, 2026
Recorded effective date
Sep 9, 2026

Selected exposure values

These values need the scope, limit type and averaging period shown below. A proposed or advisory value is not a binding limit.

Aluminium welding fumes

1 mg/m3
Averaging period8-hour TWA
Limit typeWES
ScopeACT workplaces under WHS regime

What this could mean for your IH program

Apply the ACT commencement date when comparing historical samples.

Confirm applicability with a qualified practitioner before changing your program.

Questions and qualifications

  • Regulator article is dated 19 August; the alerts index displays 17 August. Article date used.

Source evidence

  1. Reduction in workplace exposure standards for aluminium welding fumes

    WorkSafe ACT · 19 August 2026; commencement paragraph

    ACT adoption of aluminium welding 1 mg/m3 8-hour TWA commenced 9 September 2026.

  2. Work Safety Group

    ACT Government · Updated aluminium welding fumes workplace exposure standard

    Confirms 9 September 2026 commencement and the reduction from 5 to 1 mg/m3.

Managing your IH program

Explore how LEAP IH supports industrial hygiene data management and risk assessment.

Explore LEAP IH

See a missing update or a correction? Contact APT with this page and the official source.